BlastIQ™ Mobile - Underground Record Water and Temperature

full-colour-blastIQ-logo-landscape.png

Release Date:

26th August 2026

Summary

BlastIQ™ Mobile (Underground) enables operators to record water and temperature conditions in a hole during the prep and charging workflow.  Capturing this data supports better QA/QC outcomes by giving teams visibility into hole conditions.

Water can be recorded either as a simple presence indicator (wet or dry) or a precise depth or amount measurement, depending on how the site has configured water capture.  Temperature is recorded as a numeric reading in either Celsius or Fahrenheit.

BIQ Admin Portal Configuration

Follow the steps below to enable water presence capture and temperature.

  1. Select a site and click the "BlastIQ Mobile Configuration" menu.
  2. Click the "Edit" button.

    Steps1and2.png

  3. By default, "Enable water presence capture" is true.  Untick the checkbox to enable water depth/amount recording instead of a simple wet/dry indicator.
  4. Tick the checkbox "Enable temperature capture" to enable it.
  5. Click the "Save" button when done.

    Steps3-5.png

BlastIQ™ Mobile
Enable water presence capture Temperature Editing and Deleting
  • If the "Enable water presence capture" is set to False (No):
    • Operators can record a water measurement against the hole.
    • Two preferences toggles become visible under Ways of Working in preferences, allowing the site to configure how that measurement is captured:
      • Water measuring method: Amount of or Depth to
      • Default water measurement type: Body of water or Wet Sides

Preferences.png

To record a water measurement against a hole:

  1. Navigate to Prep or Charge view.
  2. Locate the hole and tap the water field.
  3. Input the water measurement using water editor.
  4. Tap OK when done.

Note: Depending on the configured Water measuring method and Default water measurement type, the label on the modal will differ for example: Amount of Water, Depth to Water, Amount of Wet Sides, or Depth to Wet Sides.  Read more on Measure Water After Backfill or Stand-off

Water.png

 

  • If the "Enable water presence capture" is set to True (Yes):
    • Operators can mark a hole as wet or dry, rather than recording a specific water measurement.  Read more here.
    • The two water preferences toggles "Water measuring method & Default water measurement type" are hidden.

Yes.png

To mark a hole as wet or dry:

  1. Navigate to Prep or Charge view.
  2. Locate the hole and tap the wet field.
  3. Select Yes or No.
  4. Tap OK.

Wet.png

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request