Purpose
This document explains how to design a traffic management plan (TMP) map for a blast, share it with the BlastIQ™ site, and use it on the bench. It covers the full process from the design in Next Gen SHOTPlus™ to the review and updates in BlastIQ™ Insights/Mobile.
The TMP helps everyone on the bench understand:
- Where vehicles and people enter and exit the blast area.
- Which areas are no-go areas.
- How traffic should move around the pattern.
- Any other hazards or controls specific to the blast.
Before you start
- The blast design is available in Next Gen SHOTPlus™ BlastIQ™ Insights.
- You have access to the correct site in BlastIQ™.
- The BlastIQ™ site has been configured with Required Blast Documentation (Job Pack) to allow file sync to BlastIQ™ Mobile devices.
- The BlastIQ™ Mobile app is installed on the device used on the bench, and you are signed in.
- The mobile device can download the file before going to the bench, in case there is no network signal.
Workflow overview
| Step | Action | Tool |
| 1 | Design the blast and add the TMP markup | Next Gen SHOTPlus™ |
| 2 | Export the design to PDF | Next Gen SHOTPlus™ (print to PDF) |
| 3 | Upload the PDF to the BlastIQ™ site | BlastIQ™ Insights (job pack) |
| 4 | Review the TMP on the bench | BlastIQ™ Mobile |
| 5 | Mark up changes if bench conditions change | BlastIQ™ Mobile |
Step 1: Design the blast and TMP markup in Next Gen SHOTPlus™
Complete the blast design first, then add the traffic management markup on top of it in a new layer.
- Open the blast design in Next Gen SHOTPlus.
- Confirm the pattern, holes and design details are final, or close to final.
- Make sure the site map or background layer is visible, so roads, ramps and the bench edge show on the plan (if available).
- Add the TMP markup described below.
- Check that the markup is clear and easy to read when zoomed out.
- Save the design.
What to mark up
| Item | What to show |
| Entry and exit points | Where vehicles and people enter and leave the blast area, including the access road or ramp. |
| No-go areas | Areas that must not be entered, such as soft / unstable ground, or the area below a highwall or close to the low wall. |
| Traffic flow | Direction of travel for vehicles, with arrows. Show one-way routes and turning areas. |
| Loading sequence | The sequence the blast will be loaded, with arrows. |
| Parking and staging areas | Where the blasting crew, explosives trucks and support vehicles should stop/park up. |
| Other hazards | Water, wet holes, overhead power lines, edges, soft ground or anything else specific to this bench. |
Use the same colours and symbols on every blast so the plans are familiar to the crew. Follow the site's standard if one exists.
Step 2: Export the design to PDF
- In Next Gen SHOTPlus™, set the view so the whole blast and all TMP markup are visible.
- Choose the print option (Reporting > Plan) and select a PDF printer (print to PDF) as the printer.
- Choose a paper size and orientation that suit the plan. Use a larger paper size if the markup is hard to read.
- Check the print preview. Make sure the markup and hole labels are readable.
- Save the PDF with a clear name, for example: Site_Bench_BlastID_TMP.pdf.
- Open the saved PDF and check it before you upload it.
Step 3: Upload the PDF to the BlastIQ™ site
- Sign in to BlastIQ™ Insights and open the correct site.
- Go to File Storage > Blast Files and select the blast.
- Upload the TMP PDF to the correct required document.
- Check that the file appears with the right name and opens correctly.
- Check that the right people have access to the file, including the crew who will use BlastIQ™ Mobile.
Step 4: Review the TMP on the bench in BlastIQ™ Mobile
- Open BlastIQ™ Mobile and select the blast and select Measure & Load.
- Select the Blast file button
- Select the Sync button and open the file using the File view button.
Step 5: Mark up changes if bench conditions change
Conditions can change after the TMP map is made. Examples include a blocked access road, a new wet area, or a change in where vehicles need to park.
- Open the TMP file in BlastIQ™ Mobile.
- Use the markup tools to mark the change on the plan. For example, draw a new no-go area or change the traffic flow arrows.
- Add a short note that says what changed and why.
- Save the marked-up file and re-sync with BlastIQ™.
Tips
- Keep the plan simple. Too much detail makes it hard to read on a phone or tablet.
- Use clear colours and arrows.
- Download the file before going to the bench, in case there is no signal.
- Include the blast ID and date on the PDF so it is easy to match to the right blast.
- Remove or replace old versions of the TMP so the crew only sees the current one.